Tank container C14L21HP

A 21,000-litre T14 tank container for hydrogen peroxide, including high-concentration product. The manual specifies UN 2014 and UN 2015 cargoes. Equipment includes level and temperature monitoring and a self-contained explosion-protected battery supply for the instrumentation.

About the product

  • TypeT14
  • Volume21,000 l
  • Head and shell materialAD0 aluminium to TU 1-802-472-2017
  • Dimensions to ISO 668:2020, 1CC (20 ft)6058x2438x2591 mm
  • Tank container tare weight6300 kg±2%
  • Maximum gross weight36000 kg
  • Maximum payload29700 kg
  • Operating pressure, MPa0.4
  • Test pressure, MPa0.6
  • Operating temperature range-40℃ ... +50℃
  • ApplicationHydrogen peroxide, including high-concentration product: UN 2014 and UN 2015
  • ManufacturerSespel
  • Self-contained power supplyExplosion-protected VIP-AKB battery, 24 V; voltage monitored by a voltmeter

Contact us for more information about this product.

Send an enquiry
no-imgTank container C14L21HP
Complete the form to make an enquiry or request more information. Our team will contact you.
Send enquiry

Error

Description

C14L21HP is a 21,000-litre T14 tank container for hydrogen peroxide, including highly concentrated product. It combines an aluminium vessel, thermal insulation, loading and unloading equipment, and cargo monitoring with an independent power supply. The container is intended for road, rail and sea transport, loading and unloading operations, and temporary storage.

Version for hydrogen peroxide UN 2014 and UN 2015

Operating manual C14L21HP-0.0000-01RE covers hydrogen peroxide solutions UN 2014 and UN 2015. It specifies 20–60% for UN 2014 and particular stabilised, highly concentrated products containing more than 70% for UN 2015. This scope does not automatically cover any concentration or other chemical cargo: compatibility must be checked against the product and individual container documentation.

The shell and elliptical heads in contact with the product are made of AD0 aluminium. The manual separately describes preparation of the internal surface: mechanical cleaning, degreasing and chemical passivation, or a special coating. Material selection is therefore only part of the vessel requirements; surface condition and preparation also matter when handling peroxide.

Baffled vessel in a twenty-foot frame

The welded vessel consists of a cylindrical shell and two elliptical heads. Baffles divide the interior into sections no larger than 7,500 litres. They limit liquid movement during transport but do not turn the tank into separate compartments for different products. Vessel flanges accommodate the process equipment.

The frame has 1CC dimensions of 6,058 × 2,438 × 2,591 mm. Its posts and longitudinal and transverse beams connect to corner fittings used for handling, securing to a vehicle and stacking. Contact pads on the base distribute vertical loads during chassis transport.

Capacity, pressure and filling conditions

  • Geometric capacity21,000 litres
  • Head and shell materialAD0 aluminium to TU 1-802-472-2017
  • Working pressure0.4 MPa (4 bar)
  • Test pressure0.6 MPa (6 bar)
  • Tare weight according to the manual6,300 kg ±2%
  • Maximum gross weight36,000 kg
  • Insulation thickness50 mm

The geometric capacity of 21,000 litres does not authorise filling the vessel completely. The manual determines the filling ratio from product properties and temperature conditions; its example calculation applies to specified input values. Both permissible filling and cargo mass must be checked for each load. The 0.6 MPa test pressure is not a permissible operating pressure either.

Insulation and temperature monitoring serve different purposes

The 50 mm insulation reduces heat exchange between the vessel and its surroundings. External cladding is made of 08Kh18N10 steel. Climatic version U1 is designed for ambient air from −40 to +50 °C. This range describes the container operating environment, not the permissible temperature of the peroxide itself.

Insulation is not active refrigeration and does not keep temperature constant. The tank container therefore has separate product temperature measurement. Readings must be monitored against the requirements for the specific cargo; insulation does not replace that monitoring.

Three containment boxes and an equipment compartment

Equipment is arranged in three containment boxes and an equipment compartment. The boxes have drainage for moisture and spilled product. The front box groups the DN50 liquid line, gas/vapour drainage, a pressure gauge and a sampling device. The central box contains the DN500 manway with a rupture-disc safety device in its cover.

The rear box houses the safety valve with a rupture disc and monitoring gauge, the level instrument and the temperature transmitter. The gauge between the disc and valve monitors the disc, a different function from measuring vessel pressure. The supplied tank container documentation defines the equipment and specific safety fitting versions.

Sampling at two levels without opening the manway

The sampling device connects to two vessel levels, approximately 10% and 40% of the height above the bottom of the shell. Quick-release couplings allow sampling equipment to be connected without opening the manway. This provides access to the product at different heights; the manual and peroxide handling requirements govern the procedure and equipment preparation.

Radar level measurement and temperature sensing

The SENS UR-2 level instrument directs a radio signal towards the liquid surface and measures distance from its reflection. Product level is calculated using the instrument installation height. The MS-K-500 indicator displays fill percentage and volume in cubic metres, allowing cargo conditions to be observed during transfer operations and while parked.

The SENS PT transmitter measures temperature using sensors distributed along its length. Its controller processes their signals and transmits an average temperature to the indicator. Separate instruments therefore measure level and temperature, with the results available on a shared indicator in the equipment box.

Self-contained power for instrumentation

When connected to the carrier vehicle, power is supplied through a 7pin S ISO 3731 connector. An explosion-protected 24 V VIP-AKB battery, designated 1Ex with IP66 protection, allows readings to be viewed without the tractor unit. The equipment box houses the indicator, battery, on/off control and a voltmeter for monitoring the current voltage.

The independent supply powers measurement instruments; it does not cool the peroxide or drive a pump. No fixed operating duration is claimed here. The manual instructs operators to switch off the battery to avoid deep discharge and recharge when possible; charging at sub-zero temperatures is not recommended. Maintenance follows the battery and container documentation.

C14L21HP operating manual

C14L21HP-0.0000-01РЭC14L21HP operating manual with amendments 1 and 2PDFOpenUnknown

Certificates

2.3.1 25.04.01.00100.431CSCPDFOpenUnknown
2.3.4 25.04.01.00102.431Design type approvalPDFOpenUnknown
2.4.2 25.04.01.00101.431Customs Convention on ContainersPDFOpenUnknown

Compatible fittings

Useful information

Frequently asked questions

Answers to questions about selecting, connecting and operating the product.

Which cargoes are specified for C14L21HP?

Hydrogen peroxide UN 2014 and UN 2015, including high-concentration product. Concentration and operating conditions must match the documentation for the particular tank and cargo; this is not a general-purpose specification for arbitrary chemicals.

Can cargo be monitored without tractor power?

Yes. An explosion-protected 24 V battery supplies level and temperature monitoring. Battery voltage is monitored with a voltmeter.

Does the insulation maintain a constant temperature?

Insulation reduces heat exchange with the surroundings but is not an active cooling system. Peroxide temperature must be monitored at acceptance and during transport.

Can samples be taken without opening the manhole?

Sampling connections are provided at 10% and 40% of the vessel height. Sampling procedures follow the manual and requirements for the particular product.