Safety valve 09262.6522.11The 09262.6522.11 is a DN65 pressure/vacuum relief valve for tank containers carrying liquid cargoes. It combines an overpressure relief assembly and a vacuum valve in one body. The technical specifications identify a set pressure of 2.19 bar for version .6522.11, with a protective guard and screen.
The valve responds to pressure changes in the vessel’s gas space during unloading, loading and storage. It needs no electrical power or control signal: pressure differences and spring forces move the closure elements. They return to their seats when the specified conditions are restored.
As pressure rises, the pressure valve overcomes its spring force and lifts from the body seat. Gas leaves the vessel through the resulting gap. When pressure falls, the spring presses the closure back onto its seat and stops discharge.
Under vacuum, the second assembly operates. Atmospheric air entering through body openings acts on the vacuum valve, opening it against its spring and connecting the gas space to atmosphere. The vacuum valve sits within the pressure-valve assembly, enabling both functions through a single vessel connection.

09262 family construction: pressure and vacuum valves, protective screen and design options
The body forms the main valve seat, while the pressure valve itself forms the vacuum-valve seat. Separate springs and sealing rings serve the two closure elements. The body and cover are AISI 316; the technical specifications identify F-4MB fluoropolymer seals.
The screen covers access to the internal components and is specified as a protective element. Its presence does not replace checking compatibility with the cargo. Screen cleanliness, free closure movement and sealing-surface condition matter for both functions.
Check the vacuum actuation threshold in the product passport. The supplied documents list 0.21 bar in the table but 0.021 bar in the marking example. Until clarified by the manufacturer, neither value should be treated as the confirmed setting of the supplied valve.
The technical specifications provide for tank-container installation with a flanged connection, vertically with the outlet upwards. The location must allow inspection, cleaning and checking of seals. Connection dimensions and clearance above the valve are checked against the individual tank-container documentation.
The family documentation includes versions with and without a vacuum assembly and options for pressure-gauge connection. These options do not imply identical equipment on every 09262 valve. Orders specify the full number 09262.6522.11, medium and settings required by the vessel passport.
The manual calls for external inspection at installation and every three months, and opening/closing checks annually. Checks cover damage, leak-tightness, mounting and intact seals. The schedule provides for seal replacement every five years, taking account of product condition and operating conditions.

Assembly disassembly and seal replacement diagram from manual 09.262-0000
If medium leaks through, inspect the pressure- and vacuum-valve seals. After ring replacement, the manual requires pressure setting and testing. Repair therefore does not end with reassembly: closure operation and leak-tightness of the restored device must be verified.
The attached manual is designated 09.262-0000RE and titled Type 09262 Safety Valve. The technical specifications identify tank-container use and version 09262.6522.11. Use the passport to select the supplied product: individual marking examples and manual wording describe the family and must be matched to the actual configuration.
| 09.262-0000РЭ | Type 09262 valve operating manual | Open | Unknown |
Answers about the purpose and selection of this tank-container version.
No. Its purpose is overpressure protection. Normal process-line isolation uses the shut-off valves specified in the system design.
No. DN65 specifies the bore. For 09262.6522.11, the technical specifications separately state a 2.19-bar set pressure; check the vacuum setting in the passport.
Check approval for the specific medium and all wetted materials, including seals. The steel designation alone is insufficient.
Provide the tank-container model, complete valve designation, medium, set pressure and passport connection dimensions.