Error

текст ошибки

Main image
Thumbnail 1Thumbnail 2Thumbnail 3

Safety valve G1 1/4

The G1 1/4 safety valve protects bulk-material tanks against pressure exceeding the allowable limit. When the actuation pressure is reached, the valve releases excess process medium; discharge stops when pressure falls to the closing value.

About the product

  • Nominal boreDN25
  • Flow capacity at 1 MPa459 m³/h
  • Flow capacity at 2 MPa752 m³/h
  • Body materialLS58-2 brass to GOST 15527-2004
  • Nominal pressure, MPa0.25
  • Medium temperature-40℃ ... +200℃
  • Type4977.09.167
  • Part number2100001647
  • ManufacturerSespel

Contact us for more information about this product.

Send an enquiry
no-imgSafety valve G1 1/4
Complete the form to make an enquiry or request more information. Our team will contact you.
Send enquiry

Error

Description

The G1 1/4 safety valve protects bulk-material tanks against pressure exceeding the allowable limit. When the actuation pressure is reached, the valve releases excess process medium; discharge stops when pressure falls to the closing value.

Design features

  • Nominal bore: DN 25; connection designation: G1 1/4.
  • Nominal pressure PN: 0.25 MPa (2.5 bar). This is a valve rating, not the actuation pressure setting.
  • Body material: LS58-2 brass.
  • Process medium temperature range: −40 to +200 °C.

Application and selection

Used on tanks carrying bulk materials, including flour, cement and animal feed. Selection requires checking the tank’s allowable pressure, the valve setting and the required flow capacity against the documentation for the specific version. Process medium temperature must be distinguished from allowable ambient temperature.

Selection for a pneumatic unloading system

For pneumatic tank unloading, the valve is assessed together with the air supply and the vessel being protected. Selection requires tank parameters, the working medium and air supply data. The selected version’s relieving capacity and setting must be matched to those conditions using the documentation; the G1 1/4 thread size is only one connection parameter.

Identifying the version for replacement

When replacing a valve, retain the designation, setting and capacity rating conditions from the installed valve’s markings and passport. These details help distinguish visually similar products with different operating parameters. Matching the connection and body material does not replace verification of suitability for the particular tank.

Useful information

Frequently asked questions

Answers to questions about selecting, connecting and operating the product.

Does PN 0.25 MPa mean the actuation pressure?

No. PN is the valve nominal pressure. Check the actuation setting, closing pressure and required flow separately against the version documentation and protected tank parameters.

Can the valve be selected solely by the 752 m³/h flow figure?

No. Comparison requires the conditions under which the flow was measured, including medium and pressures. Without them, the figure does not establish suitability for a particular tank.

Does the range up to +200 °C apply to ambient air?

On this page it refers to process medium temperature. Check allowable ambient temperature and the specific version limits separately in the product documentation.