Error

текст ошибки

Main image
Thumbnail 1

Fuel tanker vent valve

The road tanker breather valve regulates pressure in the compartment vapour space: it releases the vapour-air mixture under excess pressure and admits air under vacuum. It is installed on the tank inspection hatch.

About the product

  • Nominal boreDN 32 mm
  • Male threadG1 ¼
  • Dimensions65x65x120 mm
  • Weight0.4 kg
  • Excess pressure, MPamaximum 0.012
  • Vacuum pressure0.4–2.5 kPa
  • Flow capacity41 m³/h
  • Operating temperature range-47℃ ... +65℃
  • Body materialAK12 aluminium alloy to GOST 1583-93
  • Part number2100001656
  • ManufacturerSespel

Contact us for more information about this product.

Send an enquiry
no-imgFuel tanker vent valve
Complete the form to make an enquiry or request more information. Our team will contact you.
Send enquiry

Error

Description

The road tanker breather valve regulates pressure in the compartment vapour space: it releases the vapour-air mixture under excess pressure and admits air under vacuum. It is installed on the tank inspection hatch.

Design features

  • Nominal bore: DN 32; male thread: G1 ¼.
  • Excess pressure: no more than 12 kPa; vacuum pressure: 0.4 to 2.5 kPa.
  • AK12 aluminium alloy body.

Application and selection

Used on road tankers, tank trailers and tank semi-trailers. Replacement requires checking the thread, mounting dimensions and actuation parameters; the same intended function alone does not establish interchangeability.

Compartment breathing and vapour return

The breather valve and vapour return system serve different purposes. The valve responds to pressure changes in the vapour space, while the return system provides a vapour path during loading and unloading operations. A vapour return line therefore does not remove the need to select the breather valve against the compartment’s permissible pressure and vacuum.

Details for specifying a replacement

For a replacement enquiry, provide the previous valve designation and compartment details, together with the product passport or identification markings. This helps match breathing parameters to operating conditions rather than selecting solely by the threaded connection. The values in this product description are not instructions for readjusting an installed valve.

Useful information

Frequently asked questions

Answers to questions about selecting, connecting and operating the product.

How does the valve respond to pressure and vacuum?

It releases the vapour-air mixture under excess pressure and admits air under vacuum, regulating the compartment vapour-space pressure within the limits of its version.

Where is the breather valve installed?

It is installed on the compartment inspection hatch. This product is listed as DN 32 with a G1 ¼ male thread; check the mounting and dimensions before replacement.

Can a replacement be selected solely by its G1 ¼ thread?

No. Also check actuation pressures, flow capacity, process medium and temperature limits. Matching threads do not make valves interchangeable.

HomeNews