Error

текст ошибки

Main image
Thumbnail 1Thumbnail 2Thumbnail 3Thumbnail 4

Cryogenic safety valve 09260.2300.50

About the product

  • VersionFor tank containers; not for road tankers
  • Nominal boreDN25
  • Weight3.8 kg
  • Body materialAISI 304 steel, ASTM A240
  • Operating pressure, MPa5.0
  • Climatic versionV1 climatic version (−60°C to +50°C)
  • VersionWith manual test-lift mechanism
  • Working mediumRefrigerated liquefied gases and their mixtures (nitrogen, argon, oxygen, methane, chlorotrifluoromethane, nitrous oxide, ethane, ethylene, carbon dioxide, carbon monoxide, krypton, trifluoromethane, LNG, liquefied natural gases)
  • Operating temperature -196℃ ... +120℃
  • CertificationRussian Maritime Register of Shipping, TR CU 010/032, ADR, IMDG Code, RID
  • Type09260.2300.50
  • ManufacturerSespel

Contact us for more information about this product.

Send an enquiry
no-imgCryogenic safety valve 09260.2300.50
Complete the form to make an enquiry or request more information. Our team will contact you.
Send enquiry

Error

Description

The 09260.2300.50 is a low-temperature spring-loaded safety valve with a lifting lever for cryogenic tank containers. It opens a discharge passage when the set pressure is exceeded and closes it again as pressure falls. The valve operates directly from medium pressure, without electrical power, a pneumatic actuator or an external opening command.

The angle-pattern body combines an inlet passage and a side outlet. The guide, stem and setting spring sit above the closure assembly, with the functional-check mechanism at the top. This arrangement separates automatic pressure actuation from checking operation with the lifting lever.

How the spring controls pressure relief

During normal operation, the spring presses the disc against the inlet seat through the closure assembly. Medium pressure acts on the opposite side of the disc. When its force overcomes the spring force, the disc lifts and medium flows towards the side outlet. The manual describes proportional action: disc lift is related to the amount by which pressure exceeds the threshold.

After relief, pressure on the disc falls and the spring returns it to the seat. The PTFE seal on the disc closes the passage and stops further discharge. A ball between the disc and stem centres the connection; the disc design also resists rotation during pulsation and vibration while open.

Valve section and principal components

Model 09260 construction from the manual: general view, spring assembly section and lifting mechanism

Model 09260 construction from the manual: general view, spring assembly section and lifting mechanism

Gland seal replacement: valve assembly breakdown, Figure 2 from operating manual 09.260-0000RE

Gland seal replacement: valve assembly breakdown, Figure 2 from operating manual 09.260-0000RE

The manual drawing shows the components of the 09260 family. The body and ports form a threaded assembly. The guide positions the stem, while the spring-adjusting nut and locknut set and secure spring force. These are safety-device setting components, not controls for routine flow operation.

  • Body and portsAISI 304 stainless steel, as listed in the manual
  • Disc, guide and stem12Kh18N10T steel, as listed in the manual
  • Disc sealPTFE seal secured to the disc by a washer and nut
  • Checking mechanismLifting lever, shaft and return spring

Purpose of the lifting lever

The lifting mechanism allows checking movement and flow through the valve. The manual associates this check with initial commissioning, return to operation after a shutdown and periodic inspection. It is also used to help prevent sticking, seizure and freezing of the closure assembly.

Operating the lever moves the stem through the shaft and compresses the spring; internal pressure assists disc opening. Releasing the lever lets the return spring restore the mechanism. Checks follow the manual conditions: the lever is not intended to change the set pressure or continuously regulate flow.

Installation on a cryogenic tank container

The manual specifies vertical installation with a side outlet and threaded connection. Flow direction is checked against the arrow on the body. Space around the spring housing and lever provides inspection and maintenance access; discharge routing follows the tank-container safety-system arrangement.

The body must not carry bending, tension, torsion or misalignment loads from the piping. Protective plugs remain in place until connection to keep contaminants out. Installation is followed by seat leak-tightness and functional checks; a matching thread alone is not sufficient for acceptance.

Leak-tightness checks and maintenance

External inspection checks for damage, leakage and intact seals. The manual identifies seat contamination, seal damage and vibration as possible causes of leakage. Continuous discharge or failure to activate requires checking the valve and operating conditions, including discharge-line back pressure.

  • Inspection under the manualAt installation and at least once every three months
  • Functional checkAnnually, including a lifting-function check
  • Scheduled seal replacementEvery five years; faults require action based on inspection findings

Maintenance intervals are reviewed against system operating conditions. Repairs are performed by an appropriately authorised organisation after depressurisation. Following seal replacement, the manual requires valve setting and testing; installing a new part alone does not complete maintenance.

Set pressure and the 09260.2300.50 version

The set pressure is selected for the individual vessel and medium. It differs from the valve’s working and test pressures. Ordering this version requires the valve passport data, tank-container parameters and inlet and discharge connection details.

The documents below describe the 09260 family and include versions with opening pressures of 8 and 10 bar. These values, along with dimensions and temperature limits in the general tables, do not automatically establish the parameters of version 09260.2300.50; its passport determines the final data.

Model 09260 operating manual

09.260-0000РЭModel 09260 low-temperature safety valve operating manualPDFOpenUnknown
Useful information

Frequently asked questions

Answers about the purpose and selection of this tank-container version.

Does the valve need electrical power?

No. This direct-acting valve operates through the balance of medium pressure and spring force.

Does the valve close after relieving pressure?

It is designed to reseat when normal operating conditions are restored. The cause of activation and the valve condition must be checked before further operation.

Can 5 MPa be treated as the opening pressure?

No. Working pressure and set pressure are different parameters. Check the individual valve passport and markings for its setting.

Will any 09260 valve fit the same tank container?

No. The version, setting, connections and medium approval must match. The model number alone is insufficient.