Cryogenic check valve 09256.1050.20

About the product

  • VersionFor tank containers; not for road tankers
  • Nominal boreDN 10 mm
  • Connection typeLap-weld connection
  • Weight0.7 kg
  • Body materialAISI 304 steel, ASTM A240
  • Operating pressure, MPa5.0
  • Climatic versionV1 climatic version (−60°C to +50°C)
  • Working mediumRefrigerated liquefied gases and their mixtures (nitrogen, argon, oxygen, methane, chlorotrifluoromethane, nitrous oxide, ethane, ethylene, carbon dioxide, carbon monoxide, krypton, trifluoromethane, LNG, liquefied natural gases)
  • Operating temperature -196℃ ... +120℃
  • CertificationRussian Maritime Register of Shipping, TR CU 010/032, ADR, IMDG Code, RID
  • Type09256.1050.20
  • ManufacturerSespel

Contact us for more information about this product.

Send an enquiry
no-imgCryogenic check valve 09256.1050.20
Complete the form to make an enquiry or request more information. Our team will contact you.
Send enquiry

Error

Description

This is a dedicated tank container version. It is intended for tank container fittings, not for installation on road tankers. Selection must take into account the tank container model, working medium and parameters of the specific version.

The 09256.1050.20 cryogenic check valve is designed to prevent reverse flow of refrigerated liquefied gases and their mixtures. Its body is made of AISI 304 stainless steel.

Model 09256.1050.20 has a lap-weld connection.

Design features

  • Nominal bore: DN 10.
  • Working pressure: 5.0 MPa.
  • Operating temperature range: −196 to +120 °C.

Application and selection

Used in piping for cryogenic equipment and refrigerated gas storage and transport systems where reverse flow of the process medium must be prevented.

Role of the check valve in a cryogenic line

Model 09256.1050.20 is selected for a section where reverse flow must be prevented. This function differs from manually isolating a section for maintenance. If the arrangement requires both reverse-flow prevention and controlled shut-off, consider each component’s function separately.

Matching the DN 10 piping

Before installation, check flow direction, permitted mounting orientation and lap-weld connection dimensions against the product documentation. To assess low-flow operation, also request cracking pressure and pressure-drop characteristics. The 5.0 MPa working pressure does not replace these data or indicate the differential pressure at which the valve opens.

Useful information

Frequently asked questions

Answers to questions about selecting, connecting and operating the product.

How does a check valve differ from a shut-off valve?

A check valve is intended to prevent reverse flow. It should not replace an operated shut-off valve where deliberate pipeline isolation is required.

What connection does 09256.1050.20 have?

This model has a DN 10 bore and a lap-weld connection. Check branch dimensions and installation direction against the drawing and product markings.

At what differential pressure does it start to open?

Cracking pressure is not specified on this page. The 5.0 MPa working pressure is not the cracking pressure; consult the documentation for the selected version.