текст ошибки


Contact us for more information about this product.
Cryogenic check valve 09256.1050.20This is a dedicated tank container version. It is intended for tank container fittings, not for installation on road tankers. Selection must take into account the tank container model, working medium and parameters of the specific version.
The 09256.1050.20 cryogenic check valve is designed to prevent reverse flow of refrigerated liquefied gases and their mixtures. Its body is made of AISI 304 stainless steel.
Model 09256.1050.20 has a lap-weld connection.
Used in piping for cryogenic equipment and refrigerated gas storage and transport systems where reverse flow of the process medium must be prevented.
Model 09256.1050.20 is selected for a section where reverse flow must be prevented. This function differs from manually isolating a section for maintenance. If the arrangement requires both reverse-flow prevention and controlled shut-off, consider each component’s function separately.
Before installation, check flow direction, permitted mounting orientation and lap-weld connection dimensions against the product documentation. To assess low-flow operation, also request cracking pressure and pressure-drop characteristics. The 5.0 MPa working pressure does not replace these data or indicate the differential pressure at which the valve opens.
Answers to questions about selecting, connecting and operating the product.
A check valve is intended to prevent reverse flow. It should not replace an operated shut-off valve where deliberate pipeline isolation is required.
This model has a DN 10 bore and a lap-weld connection. Check branch dimensions and installation direction against the drawing and product markings.
Cracking pressure is not specified on this page. The 5.0 MPa working pressure is not the cracking pressure; consult the documentation for the selected version.