текст ошибки



Contact us for more information about this product.
Cryogenic shut-off valve 09241.1550.14.1This is a dedicated tank container version. It is intended for tank container fittings, not for installation on road tankers. Selection must take into account the tank container model, working medium and parameters of the specific version.
The 09241.1550.14.1 manually operated cryogenic shut-off valve is designed to shut off the flow of refrigerated liquefied gases and their mixtures. It has an AISI 304 stainless steel body and a nominal bore of DN 15.
Model 09241.1550.14.1: butt-weld connection; valve height H: 270 mm.
The valve is used in piping for refrigerated liquefied gas storage and transport systems. Selection takes account of the nominal bore, connection type and valve height H.
Model 09241.1550.14.1 provides manual shut-off for a DN 15 line. Unlike the DN 10 version, it has butt-weld connections and a height H of 270 mm. When changing to this model, check body position and operating access as well as the pipeline diameter.
The AISI 304 body and listed temperature range form part of the selection data. For a particular gas or mixture, also confirm seal materials and product preparation requirements. The steel grade alone does not establish suitability of the complete assembly for every medium.
Answers to questions about selecting, connecting and operating the product.
This version has a DN 15 bore and a butt-weld connection. Check branch dimensions against the drawing before installation; matching DN alone is not sufficient.
Valve height H is 270 mm. The layout must also allow access for manual operation and maintenance; check the required clearance against the installation drawing.
Matching bore size is not enough. Compare connections, height, operating pressure and temperature, materials and compatibility with the specific medium. This valve is manually operated.