текст ошибки


Contact us for more information about this product.
Pneumatically actuated cryogenic shut-off valve 09240.6550.12This is a dedicated tank container version. It is intended for tank container fittings, not for installation on road tankers. Selection must take into account the tank container model, working medium and parameters of the specific version.
The 09240.6550.12 pneumatically operated cryogenic shut-off valve is designed to shut off the flow of refrigerated liquefied gases and their mixtures. It has an AISI 304 stainless steel body and a nominal bore of DN 65.
Model 09240.6550.12: butt-weld connection; number of springs: 2.
The valve is used in refrigerated liquefied gas storage and transport systems with pneumatically operated shut-off valves. Selection takes account of the nominal bore, connection and actuator configuration.
Valve 09240.6550.12 differs from model 09240.5050.11 in its DN 65 bore and two springs. A larger nominal bore does not by itself specify flow capacity: assessing pressure loss requires the medium, required flow and valve flow characteristic. A change from DN 50 to DN 65 should therefore be checked against the piping requirements, not just the pressure designation.
The body has butt-weld connections. Allow access to the actuator and its pneumatic connections, and check weld-end dimensions against the selected version drawing. Confirm the position on loss of control air and the method of monitoring opening separately; the presence of two springs does not establish these functions.
Answers to questions about selecting, connecting and operating the product.
09240.6550.12 has a DN 65 nominal bore and 2 springs. Both versions have butt-weld connections. Bore and construction differences must be considered when replacing a valve.
The actuator operating pressure listed is 0.6 MPa. The 5.0 MPa process pressure is a separate rating and must not be used as the actuator supply pressure.
Specify 09240.6550.12, the process medium, its pressure and temperature, piping dimensions and pneumatic control arrangement. These details allow the valve version and actuator connection to be checked.