Loading/unloading device 09264.5040.31 (liquid phase)The 09264.5040.31 loading and unloading device is designed for the liquid-phase line of a tank container carrying liquefied petroleum gases (LPG). It enables transfer-hose connection, product loading and unloading, and leak-tight line isolation during storage and transportation. This version has a nominal diameter of DN 50 and a nominal pressure rating of PN 4 MPa (40 bar).
The assembly comprises an internal excess-flow shut-off valve, an external ball valve and an outlet sealing cap. These provide separate barriers against leakage, including when external loading and unloading components are damaged. The device is intended for tank containers; use on road tankers or in other systems requires separate approval from the manufacturer.
Dimensions and weight are for the DN 50 version in Table 3 of operating manual 09.264-0000RE. The 40 bar value is the valve assembly nominal pressure, not the excess-flow valve trip pressure. Selection for a particular operating pressure must follow the tank-container design and the product passport.

Longitudinal section of the DN 50 assembly: ball valve, internal valve and outlet cap (manual Fig. 1)

General arrangement and lever positions (manual Fig. 1)

Disassembly diagram showing the valve, ball valve and outlet connection (manual Fig. 2)

Internal structure of the spring-loaded excess-flow shut-off valve (manual Fig. 4)
The drawings are based on Figures 1, 2 and 4 of operating manual 09.264-0000RE. Component reference numbers correspond to the manufacturer's parts list; use the documentation for the specific serial number when ordering spare parts or carrying out repairs.
In the closed position, a spring and tank pressure press the valve disc against its seat. Turning the operating lever causes a cam to first open a throttling passage and equalize pressure across the valve. Once pressures are balanced, the spring lifts the main disc to open the liquid-phase passage.
If a transfer hose ruptures or flow suddenly increases, the pressure differential closes the main seat. A residual flow may still pass through the throttling passage, so the operating lever must be moved to the closed position for complete shut-off. The excess-flow mechanism does not replace operator actions or the emergency isolation system specified in the design.
The manual also describes provision for an external emergency-closing arrangement: a link to a fixed point and a return spring on the lever can close the valve if the container moves unexpectedly or is exposed to fire. This arrangement must be specified and installed for the individual site; holes in the lever do not mean all emergency system parts are included in the delivery.
Before loading or unloading, inspect the assembly, connect the hose, fully open the ball valve and excess-flow valve, and connect the specified emergency control arrangement. When the operation is complete, close both valves, disconnect the hose and refit the sealing cap.
The device is repairable. Inspection should cover the body, threaded and flanged joints, seals, smooth lever operation and complete valve closure. Technical examinations are performed as part of the tank-container inspection in accordance with applicable rules.
The operating organization may increase inspection frequency depending on service intensity and conditions. Damaged seals or components must be replaced in accordance with the manual using parts specified by the manufacturer.
Version 09264.5040.31 is for a DN 50 liquid line, while 09264.2540.31 is used for a DN 25 vapour line. The versions differ in bore, hose connection and line configuration. Before ordering, verify the designation against the tank-container design, service medium, pressure and temperature, mating flange dimensions and outlet connection.
| 09.264-0000РЭ | Operating manual for loading and unloading device model 09.264 | Open | Unknown |
Answers to common questions about design, specifications, installation and operation of device 09264.5040.31.
It is used for loading and unloading LPG through the liquid-phase line of a tank container. The DN 50 device has three successive isolation elements: an excess-flow valve, a ball valve and an outlet cap.
Nominal pressure PN 4 MPa (40 bar). Medium temperature is −60 to +80 °C and ambient temperature −60 to +50 °C. The permitted system pressure must comply with the tank-container design and passport.
The DN 50 version is specified as 355 mm long, 330 mm wide and 223 mm high, with a weight of 18.5 kg.
A sudden rise in flow automatically closes the main seat of the excess-flow valve, but residual flow through the throttling passage may remain. Complete shut-off requires moving the lever to closed and using the design-specified emergency arrangement.
No. The manual permits only fully open or fully closed operation. Partial opening and using the ball valve to throttle flow are prohibited.
Yes. The liquid-phase version has a separate plugged and gasketed threaded connection for a pressure gauge or sample take-off. Check connection size and compatibility against the drawing.
09264.5040.31 is DN 50 for the liquid line; 09264.2540.31 is DN 25 for the vapour line. They are not assumed interchangeable and must be selected for the specific tank-container line.
Inspect visually at installation and at least every three months, and perform an annual functional test. The manual specifies a 20-year design service life and 10,000 operating cycles, subject to proper operation.
The .31 version is intended for LPG tank containers. Separate .32 versions are specified for ammonia. Use on road tankers or in other conditions requires manufacturer approval.