текст ошибки


Contact us for more information about this product.
Loading/unloading device 09264.2540.31 (vapour phase)The 09264.2540.31 is a DN25 device for admitting and withdrawing vapour in an LPG tank-container loading and unloading system. It isolates the gas line during storage and transport and provides its connection during process operations. Version .31 is for LPG; documentation specifies a separate .32 version for ammonia.
The assembly connects an internal excess-flow shut-off valve, an external ball valve and an outlet closure in series. It attaches to the container by a flange on the internal-valve side, while the hose connects at the outlet. The closure seals the outlet after hose disconnection and is tethered to prevent loss.
The difference is not limited to nominal bore. The manual lists a separate length, mass and outlet wrench size for DN25. The liquid and vapour versions have different hose connections. DN25 is therefore selected for the vapour-line arrangement, rather than treated as an interchangeable smaller DN50.
The manual specifically assigns the threaded pressure-gauge or sampling port to the liquid-phase device. It is not claimed here as equipment on the 09264.2540.31. Check the hose connection type and dimensions against the supplied product drawing; wrench size is not a thread designation.
The internal excess-flow valve is held closed by its spring and vessel pressure. Turning the handle moves the stem through a cam and first opens a restricted passage. Medium begins to flow through it, equalising pressure across the main closure. After equalisation, the spring mechanism allows the main disc to lift and open the passage.
The external ball valve has a separate handle with 90-degree rotation. It is used fully open or fully closed. Intermediate positions must not be used to regulate flow; operation of both shut-off elements follows the manual and tank-container arrangement.
An abrupt flow increase, including hose rupture, creates a pressure difference that closes the internal valve’s main disc. Restricted flow may nevertheless continue through the stem throttling groove. The manual requires moving the handle to the closed position for complete closure. Excess-flow activation must therefore not be described as an unconditional immediate stop to all leakage.
For unintended container movement and fire exposure, the manual describes a separate remote-closing arrangement: a link to an external fixed point holds the valve open, and a return spring closes it when the link breaks. This system requires the specified connections; mounting the device on a flange alone does not provide it.

09264-family excess-flow valve mechanism from the manual; select the vapour-line connection for the DN25 version
The internal valve portion sits inside the vessel. The external body has a weakened groove: the manual describes the internal closed portion remaining attached to the vessel if the external assembly breaks in an accident. Body and mounting condition are therefore inspected together with seal leak-tightness.
The technical specifications define horizontal operation and flow from the excess-flow valve towards the ball valve. Installation must allow access to both handles, the outlet closure and hose connection. Check internal cleanliness, gasket condition and absence of connected-line loads that could cause misalignment.
The manual specifies external inspection at installation and at least every three months, annual functional checks, a 20-year service life and 10,000 cycles under the specified operating conditions. Maintenance distinguishes external joint leakage from leakage through closed shut-off elements. Repairs are followed by the manual’s required checks, not merely visual reassembly.
| 09.264-0000РЭ | 09264-family operating manual, including the DN25 vapour version | Open | Unknown |
Answers about the purpose and selection of this tank-container version.
For the vapour phase, with a DN25 bore. The 09264.5040.31 device serves the other phase line and is selected separately.
The .31 designation identifies LPG service. Documentation specifies .32 for ammonia; any substitution requires checking the exact version and passport.
They close the line in series: the internal valve, external ball valve and blanking closure. They are separate components, not three positions of one valve.
The device connects to the tank by a flange. Check the outlet hose connection separately against the drawing and markings; DN alone does not define it.