Error

текст ошибки

Main image
Thumbnail 1

Changeover device 09263.3250.10

About the product

  • VersionFor tank containers; not for road tankers
  • Nominal boreDN 32 mm
  • Weight18.7 kg maximum
  • Body materialBrO5Ts5S5 bronze (GOST 613-79)
  • Operating temperature−196 ... +120 °C
  • Climatic versionV1 climatic version (−60°C to +50°C)
  • Barcode09263.3250.10
  • ManufacturerSespel
  • Nominal pressure, MPa5.0
  • ConnectionThreaded: 1½-inch inlet, 1-inch outlet

Contact us for more information about this product.

Send an enquiry
no-imgChangeover device 09263.3250.10
Complete the form to make an enquiry or request more information. Our team will contact you.
Send enquiry

Error

Description

The 09263.3250.10 is a manually operated DN32 changeover device for the safety-device lines of a cryogenic tank container. A single central inlet connects the vessel to two outlet lines or isolates either one. This allows selection of the operating line when servicing safety devices according to the tank-container arrangement.

A ball with a T-shaped passage switches the flow. The handle turns the ball through the stem, aligning its passages with the body openings. The device itself does not relieve excess pressure; safety valves on the connected lines perform that function.

Three positions of the T-shaped passage

The manual specifies three operating positions: both sides open, the left side closed or the right side closed. When one outlet is isolated, the solid face of the ball blocks it while the other line remains connected to the central inlet. The handle position corresponds to the passage direction and identifies the selected configuration.

Intermediate positions are not intended for throttling; operation with the device partially closed is prohibited. Maintenance changeover follows the protection arrangement of the individual vessel so that isolating one safety device does not compromise the specified protection system.

Specifications of version 09263.3250.10

  • Nominal boreDN32
  • Nominal pressure PN5 MPa (50 bar)
  • Medium temperature−196 to +120 °C
  • Ambient temperature−60 to +50 °C, climatic version V1
  • Seat tightnessClass A to GOST 9544-2015
  • Maximum mass18.7 kg
  • Inlet connection1½-inch thread
  • Outlet connection1-inch thread

The manual lists gaseous media including nitrogen, oxygen, argon, methane and LNG. These specifications describe the device; the allowable operating conditions of the complete system also depend on the vessel and installed safety equipment. Other operating conditions require agreement with the manufacturer.

Serviceable body and stem sealing

09263 general view and sections: central passage, ball closure and stem assembly

09263 general view and sections: central passage, ball closure and stem assembly

The assembly consists of a central body and two side bodies with threaded ports. Screwed body joints provide access to internal components for repair. Additional instrumentation ports are closed with plugs; connection details are selected using the device drawing.

The central and side bodies are made of BrO5Ts5S5 bronze. The ball and stem are 12Kh18N10T steel, with PTFE seals in the closure assembly. A stem bushing acts as a plain bearing, while packing, a seal and bushings form the gland assembly that seals the stem outlet.

Disc springs preload the gland assembly through a threaded plug. Axial compression of the sealing elements establishes contact with the stem. This is a separate sealing assembly: leakage at the stem, between bodies and through the seat requires inspection of different components.

Dimensions for valve-compartment installation

  • Length L295.5 mm
  • Width a160.8 mm
  • Overall height H282.3 mm
  • Drawing dimension h127 mm
  • Flow diameter d30 mm

Any installation position is permitted; a horizontal stem is recommended. Flow enters through the central opening. Installation planning considers not only body dimensions but also handle travel, side-connection access and servicing of the connected safety devices.

Three sealing areas to inspect

Body-joint seals seal the central body to the side bodies. Ball-seat seals prevent flow into an isolated line. Gland components seal the stem where it exits the body. The manual diagrams show the location of these components and distinguish the assemblies.

Manual Figure 4: seals between the central and side bodies

Manual Figure 4: seals between the central and side bodies

Manual Figure 5: ball-seat seals

Manual Figure 5: ball-seat seals

Manual Figure 6: stem gland seal

Manual Figure 6: stem gland seal

Repairs are performed after depressurisation and in the sequence specified by the manual. Each area has its own seal-access procedure. Reassembly must preserve contact surfaces and avoid gasket damage; leak-tightness and functional checks complete restoration of the assembly.

Inspection and checking schedule

  • External inspectionAt installation and every three months: damage, markings and leak-tightness
  • Functional checkAnnually: ability to open and close
  • Seal replacementEvery five years under the manual schedule
  • Service life stated in the manual10 years

The operator determines maintenance intervals with regard to operating conditions. The stated service life does not imply operation without inspection: joint condition, smooth changeover and leak-tightness are monitored throughout service. Technical examination is performed as part of the tank container.

Operating manual and technical specifications

09.263-0000РЭModel 09263 changeover device operating manualPDFOpenUnknown
Useful information

Frequently asked questions

Answers about the purpose and selection of this tank-container version.

What is the changeover device used for?

It switches flow between safety-device lines, including for maintenance. It does not replace a safety valve.

What connections does the 09263.3250.10 have?

Threaded: a 1½-inch inlet and a 1-inch outlet. Check the dimensions and connection arrangement against the tank-container documentation.

Can it be used for continuous flow throttling?

No. The manual prohibits operation in a partially closed position. Use the specified operating positions.

What are the main parameters of this version?

DN32, nominal pressure 5 MPa, medium temperature from −196 to +120 °C, and a maximum mass of 18.7 kg, as specified in the operating manual and technical specifications.

HomeNews