Cryogenic filter 09259.5050.10

About the product

  • VersionFor tank containers; not for road tankers
  • Nominal boreDN50
  • Connection typeButt-weld connection
  • Pressure, MPaUp to 5.0
  • Body materialsteel AISI 304 (ASTM A240)
  • Fluid temperature-196℃ … +120℃
  • Climatic versionV1 climatic version (−60°C to +50°C)
  • Model09259.5050.10
  • ManufacturerSespel

Contact us for more information about this product.

Send an enquiry
no-imgCryogenic filter 09259.5050.10
Complete the form to make an enquiry or request more information. Our team will contact you.
Send enquiry

Error

Description

This is a dedicated tank container version. It is intended for tank container fittings, not for installation on road tankers. Selection must take into account the tank container model, working medium and parameters of the specific version.

The 09259.5050.10 cryogenic filter is designed to filter liquefied gases in cryogenic systems. Its body is made of AISI 304 stainless steel.

Model 09259.5050.10 has a nominal bore of DN 50 and a butt-weld connection.

Design features

  • Process medium pressure: up to 5.0 MPa.
  • Process medium temperature: −196 to +120 °C.
  • Butt-weld connection to the pipeline.

Application and selection

The filter is used in systems handling liquefied gases, including nitrogen, oxygen and LNG. Selection takes account of the process medium, pressure, temperature and connection dimensions.

Selecting the filter for the filtration task

For filter 09259.5050.10, distinguish body specifications from filter element specifications. DN 50, AISI 304 and pressure up to 5.0 MPa describe some application conditions, but do not determine the retained particle size. Specify the contaminants and required filtration rating when enquiring so the element can be selected for the task.

Flow and maintenance access

Checking flow capacity requires flow rate, process medium, temperature and allowable pressure drop. The layout should also allow inspection and maintenance access; confirm element removal method and clearance against the drawing. Determine cleaning or replacement intervals from the manual for the selected version, not nominal diameter alone.

Useful information

Frequently asked questions

Answers to questions about selecting, connecting and operating the product.

Is filter 09259.5050.10 DN 50 or DN 80?

This version is DN 50 with a butt-weld connection. When replacing it, check the full model designation and connection dimensions.

What is its filtration rating?

The filtration rating and mesh size are not specified on this page. Confirm them for the selected filter element; they cannot be inferred from the body diameter.

Does 5 MPa mean the pressure drop across the filter?

No. It is the listed process pressure limit. Filter pressure drop depends on flow rate, medium and element condition; a pressure-drop characteristic is not provided here.